Why is the electrical system not working on my Manitou MUSTANG 1050RT X?
- LlaurajonesAug 15, 2025
If the electrical system of your Manitou Compact Loader isn't functioning, start by checking if the battery disconnect switch is in the OFF position and switch it to ON. Ensure that the battery terminals and cables are clean, properly connected, and tightened. Test the battery to see if it needs recharging or replacement. Inspect the main fuse and replace it if it's blown, first addressing the over-current problem. Finally, verify that the main wiring harness connectors at the rear of the ROPS/FOPS are correctly plugged in, reconnecting or repairing them as necessary.