Section 4 Maintenance
Part Number 000007924 5/14 45
Preventative Maintenance Cleaning
Procedure
This procedure cleans all components in the water flow
path, and is used to clean the ice machine between the
bi-yearly cleaning/sanitizing procedure.
Ice machine cleaner is used to remove lime scale and
mineral deposits. Ice machine sanitizer disinfects and
removes algae and slime.
NOTE: Although not required and dependant on your
installation, removing the ice machine top cover may
allow easier access.
Step 1 Ice must not be on the evaporator during the
clean cycle. Follow one of the methods below:
Press the power switch at the end of a harvest cycle
after ice falls from the evaporator(s).
Press the power switch and allow the ice to melt.
Step 2 Open the front door to access the evaporator.
Step 3 Press the clean switch. Water will flow through
the water dump valve and down the drain. Wait until the
water trough refills and the display indicates add solution
(approximately 3 minutes), then add the proper amount
of ice machine cleaner.
Step 4 Close and secure the front door. The ice
machine will automatically start ice making after the
clean cycle is complete (approximately 24 minutes).
Cleaning the Condenser
A dirty condenser restricts airflow, resulting in
excessively high operating temperatures. This reduces
ice production and shortens component life.
Clean the condenser at least every six month.
Shine a flashlight through the condenser to check for
dirt between the fins.
Blow compressed air or rinse with water from the
inside out (opposite direction of airflow).
If dirt still remains call a service agent to clean the
condenser.
!
Caution
Never use anything to force ice from the evaporator.
Damage may result.
Model Amount of Cleaner
I06800C/I0870C/I0970C/
I1070C
5 ounces (150 ml)
IB0690C/IB0890C/IB1090C 5 ounces (150 ml)
I1470C/I1870C/I2170C 9 ounces (270 ml)
!
Warning
Disconnect electric power to the ice machine head
section and the remote condensing unit at the
electric service switches before cleaning the
condenser.
!
Warning
The condenser fins are sharp. Use care when
cleaning them.