Part Number: 000015431 Rev01 5/19 51
G. Remove distribution tubes
• Distribution tubes thumbscrews are retained to
prevent loss. Loosen thumbscrews but do not pull
thumbscrews out of distribution tube.
• Loosen the two outer screws and pull forward on the
distribution tube to release from slip joint.
• Disassemble distribution tube by loosening the two (2)
middle thumbscrews and dividing the distribution tube
into two pieces.
H. Remove the water trough
• Depress the two tabs on the top of the water trough.
• Turn left and right ice dampers down to clear water
trough.
• Pull forward on the water trough to remove.
NOTE: Proceed to page 42 Step 7.