Part Number STH025 11/16 171
Diagnostics
SYMPTOMS
Bin Switch Fails Open
G Model control boards or E Model control boards with
firmware version Rev.2.047 or higher.
• The ice machine will not start an ice making cycle and
the display indicates “Full Bin”.
• The ice machine displays “Full Bin Remove Ice” in the
clean cycle.
E Control Boards with firmware versions prior to Rev.2.047
• The ice machine will not start an ice making cycle and
the display indicates “Curtain Open”.
• The ice machine will run in the clean cycle.
Bin Switch Fails Closed
• When running a “Long Harvest” alert is displayed and
safety limit 2 indicated.
• May be off on a safety limit 2.
• The harvest cycle continues after ice opens and closes
the ice damper (harvest cycle is 3.5 minutes).