100 Part Number STH025 11/16
Control Board Timers
The control board has the following non-adjustable
timers:
• The ice machine is locked into the freeze cycle for 6
minutes before a harvest cycle can be initiated. This
can be overridden by initiating a manual harvest.
Refer to “Manual Harvest” on “Manual Harvest” on
page 85
• The maximum freeze time is 35 minutes at which
time the control board automatically initiates a
harvest sequence.
Firmware 5.009 or earlier - Maximum freeze time
is 60 minutes at which time the control board
automatically initiates a harvest sequence.
• The maximum harvest time is 7 minutes, the control
board will preform a water thaw cycle and then
return the ice machine to the freeze cycle.
Firmware 5.009 or earlier - The maximum harvest
time is 3.5 minutes. The control board automatically
initiates a freeze sequence when this time is
exceeded.
• The maximum water fill is 12 minutes.