Part Number STH025 11/16 35
Ice
Machine
Model
Refrigerant Heat of Rejection Internal Condenser
Volume (cu ft)
Design
& Burst
Pressure
Quick Connect Stubs
Male Ends
Head
Pressure
Control
ValveType Charge Average
Btu/hr
Peak Btu/
hr
Min Max 500 psig
2500 psig
Discharge Liquid
i0590 R404A 6 lbs. 6100 6900 0.020 0.035 Design
500 psig
(3447 kpa)
(34.7 bar)
Burst
2500 psig
(17237
kpa)
(172.37
bar)
coupling
P/N
8360353
coupling
P/N
8360343
P/N
8368093i0690
I0696
R404A 6.5 lbs. 9000 13900 0.045 0.060
i0890 R404A 8.5 lbs. 13000 16000 0.045 0.060
i0990
I0996
R404A 7 lbs. 13000 16000 0.045 0.060
i1090
i1190
I1196
R404A 8.5 lbs. 16250 18600 0.045 0.060
i1490
I1496
R404A 11 lbs. 23500 27000 0.085 0.105 mounting
flange P/N
8360063
mounting
flange P/N
8360053
no
substitutes
i1890 R404A 12.5 lbs. 30000 35000 0.085 0.105