Manitowoc NATIONAL CRANE 900A - ANTI-TWO BLOCK TROUBLE DIAGNOSIS - ELECTRICAL (CONTINUED)

Manitowoc NATIONAL CRANE 900A
204 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-1
72,"7^j
YESNO
NORMAL
RELAY OPERATION
$74<)$6&'$
%43'$4&
4&$3)'%%
12 volts at limit switch
Limit switch contacts closed
with weight suspended
Replace limit switch or
check actuator arm for
free movement
Check for 12 volts at
solenoid valve
Test HCAS & ATB relays for
proper operation (see
Schematic)
Check continuity
across solenoid valve
Continuity check lead
wires
Replace relay
FAULTY
RELAY OPERATION
NO
Replace solenoid
Check valve for sticking
spool - Clean or replace
YESNO
YES
Fuse blown
Test HCAS & ATB relays for
proper operation (see
Schematic)
Replace fuse
Continuity check lead
wires
Replace relay
YESNO
NORMAL
RELAY OPERATION
FAULTY
RELAY OPERATION
YES NO