–33–
HARVEST SEQUENCE WATER PURGE
Q0600C/Q0800C/Q1000C/SU1000C/QDUAL
The Harvest sequence water purge adjustment may
only be used when the ice machine is hooked up to
special water systems, such as a de-ionized water
treatment system.
The Harvest sequence water purge may be set to
15, 30, or 45 seconds.
During the Harvest sequence water purge, the water
fill valve energizes and de-energizes by time. The
water purge must be at the factory setting of
45
seconds for the water fill valve to energize during
the last 15 seconds of the water purge. If it is set to
less than 45 seconds, the water fill valve will not
energize during the water purge.
Important
The Harvest sequence water purge is factory-set at
45 seconds. A shorter purge setting (with standard
water supplies such as city water) is not recommended.
This can increase water system cleaning and
sanitizing requirements.
15
30
45
SV1208
CONTROL
BOARD
WATER PURGE
ADJUSTMENT