100 Part Number 80-1479-3 7/10
Freeze Cycle
Suction Pressure
_______ ______ _____
1 minute Middle End
If suction pressure is High or Low refer to freeze cycle high or low suction pressure problem checklist
page 115 to eliminate problems and/or components not listed on this table before proceeding.
Suction pressure is High Suction pressure is Low
or Normal
Suction pressure is
High
Suction pressure is
High
Wait 5 minutes into the
freeze cycle.
Compare temperatures of
compressor discharge line
and both harvest valve
inlets.
The harvest valve inlet is
Hot
-and-
approaches the
temperature of a Hot
compressor discharge
line.
The harvest valve inlet
is Cool enough to hold
hand on
-and-
the compressor
discharge line is Hot.
The harvest valve inlet
is Cool enough to hold
hand on
-and-
the compressor
discharge line is Cool
enough to hold hand on.
The harvest valve inlet
is Cool enough to hold
hand on
-and-
the compressor
discharge line is Hot.
S MODELS DUAL EXPANSION VALVE
Operational Analysis 1 2 3 4

Table of Contents

Other manuals for Manitowoc SY0324A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc SY0324A and is the answer not in the manual?

Manitowoc SY0324A Specifications

General IconGeneral
BrandManitowoc
ModelSY0324A
CategoryIce Maker
LanguageEnglish

Related product manuals