1.5.3
1.5.3.1
1.5.3.2
1.5.2.3
1.5.2.4
Operation Inbetriebname 1.5
Check the function of the room thermostat.
The main burners must go out at a temperature setting
below the ambient temperature.
The burners must go on again at a setting above the
ambient temperature.
Finally, check whether the operation of the unit cannot
be affected by other units, local air flows, corrosive or
explosive vapours, etc.
For a short period:
Set the room thermostat at minimum temperature.
Do not switch off the main switch at any time to
avoid any damage to the maximum and safety therm-
ostat.
Shut down of the heater.
For an extended period:
Set the room thermostat at minimum temperature.
The unit can be electrically isolated after approx. 5
min. The fan has to run to cool down the heat exchan-
ger.
Für kurze Zeit:
Den Raumthermostat auf die Mindesttemperatur einst-
ellen.
Den Netzschalter unter keinen Umsänden ausschalt-
en, da dadurch der Maximal- und der
Sicherheitsthermostat beschädigt werden könnten.
Die Funktion des Raumthermostates ist zu prüfen; ist
der Sollwert niedriger als die Umgebungstemperatur,
sollte der Brenner ausgehen. Ist der Sollwert höher als
die Umgebungstemperatur, so werden die Brenner wie-
der eingeschaltet.
Anschließend überprüfen sie bitte, ob die Funktion des
Gerätes nicht von anderen Geräten, örtlichen
Luftströmungen, korrosiven oder explosiven Dämpfen
usw. beeinflußt werden kann.
Außerbetriebsetzen des Warmlufterzeuger.
Für längere Zeit:
Den Raumthermostat auf die Mindesttemperatur
einstellen.
Nach ca. 5 Minuten kann die Stromzufuhr zum Gerät
unterbrochen werden. Ventilator muß nachlaufen und
die Wärmetauscher kühlen
23