Avoid over-twisting, -coiling, -pulling the power cord,
never use nylon or iron wire to tide the power cord.
Make sure that the plug and socket remain visible and
accessible at all the time.
Do not use extension cords.
Never reach to retrieve the unit if it has fallen in wa-
ter. In such case, immediately pull the plug. Have the unit
checked before using it again.
The appliance shall be installed in accordance with na-
tional wiring regulations.
Do not exceed the recommended room size for max.
efciency.
Close the doors and windows.
Keep curtains or blinds closed during the sunniest
hours of the day.
Keep lters clean.
Once room has reached the desired conditions, reduce
the setting for temperature and ventilation.
Do not turn on the appliance if you have discovered da-
mage to the appliance, cord or plug, if the appliance is mal-
functioning or if there are signs of any other defect. Return
the complete product to the vendor or to a certied elec-
trician for inspection and/or repair. Always ask for original
parts. The appliance (incl. cord and plug) may only be ope-
ned and/or repaired by properly authorized and qualied
persons.
Suggest to send the unit for professional maintenance
periodically.
ONLY A LICENSED PROFESSIONAL IS ALLOWED
TO DISMANTLE OR MODIFY THE APPLIANCE.
THE MACHINE IS TO BE USED ONLY FOR ITS PRES-
CRIBED PURPOSE. ANY OTHER USE IS DEEMED TO
BE A CASE OF MISUSE. THE USER/OPERATOR, NOT
THE MANUFACTUER WILL BE LIABLE FOR ANY DAMA-
GE OR INJURIES OF ANY KIND CAUSED AS A RESULT
OF THIS.
Always keep the unit in vertical position.
Keep all foreign objects away from the air intake or out-
put openings.
The mains supply must conform to the specication
shown on the rating plate at the back of the unit.
If the supply cord is damaged, it must be replaced by
an approved service representative or a similar qualied
person in order to avoid a hazard.
Never use the plug to start and stop the unit. Always
use switch on the control panel.
Before moving the unit, rst switch off, then unplug and
empty the water tank.
Don’t use bug sprays or other ammable cleaners on
the unit.
Never pour or spray water over the unit.
THIS APPLIANCE IS NOT INTENDED FOR USE BY
PERSONS (INCLUDING CHILDREN) WITH REDUCED
PHYSICAL , SENSORY OR MENTAL CAPABILITIES, OR
LACK OF EXPERIENCE AND KNOWLEDGE , UNLESS
THEY HAVE BEEN GIVEN SUPERVISION OR INSTRUC-
TION CONCERNING USE OF THE APPLIANCE BY A
PERSON RESPONSIBLE FOR THEIR SAFETY. CHILD-
REN SHOULD BE SUPERVISED TO ENSURE THAT
THEY DO NOT PLAY WITH APPLIANCE.
SAFETY RELATING TO REFRIGERANT
R290:
Read these warnings carefully.
This appliance contains the refrigerant R290. R290
is a refrigerant that complies with the relevant European
Directives. Never perforate the refrigerant circuit. R290 is
ammable (GWP3)!
Do not use means to accelerate the defrosting process
or to clean, other than those recommended by the manu-
facturer.
The appliance shall be stored in a room without continu-
ously operating ignition sources (for example: open ames,
an operating gas appliance or an operating electric heater).
Do not pierce or burn any of the components of the coo-
ling circuit of the unit. Do not set light to the unit.
The appliance shall be stored so as to prevent mecha-
nical damage from occurring.
Appliance should be installed, operated and stored in a
room with a oor area larger than 4m
2
.
Be aware that the refrigerants may not contain an
odour, which means you cannot smell leaks.
Compliance with national gas regulations shall be ob-
served.
Keep ventilation openings clear of obstruction.
A warning that the appliance shall be stored in a well-
ventilated area where the room size corresponds to the
room area as specied for operation.
Any person who is involved with working on or breaking
into a refrigerant circuit should hold a current valid certi-
cate from an industry-accredited assessment authority,
which authorizes their competence to handle refrigerants
safely in accordance with an industry recognized assess-
ment specication.
Servicing shall only be performed on the grounds as re-
commended by the equipment manufacturer. Maintenance
and repair requiring the assistance of other skilled person-
nel shall be carried out under the supervision of the person
competent in the use of ammable refrigerants.
IMPORTANT!
Do not use this unit at ambient temperatures below 5
O
C, to
prevent the possibility of a heavily ice up evaporating coil.
4. PARTS
Front FIG. 2
1. Front plate
2. Control panel
3. Air outlet
4. Handle
Rear FIG. 3
5. Castor
6. Water tank
7. Air inlet
8. Filters
5. OPERATION
Control panel FIG. 4
1. ON/OFF (power) button
2. Humidity down button
3. Humidity up button
4. Speed/Ventilation button
5. TIMER button
6. Temperature display button
7. Power indicator
8. “Full Water” indicator