EasyManua.ls Logo

Master WDM 61 - Technical Specifications and Usage Guidelines; Product Technical Data; Intended Use and Limitations

Master WDM 61
174 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14
Tool Specifications
B
* For the following situations, using a target plate is recom-
mended already for closer working ranges:
– Poorly reflecting surfaces
– Reflecting surfaces (glass, metal, etc.)
– Bright ambient light, such as direct sun light
** Under unfavourable conditions, e.g., for temperature
alterations, for a poorly reflecting surface or bright ambi-
ent light, the error of measurement can be up to 3 mm.
For working ranges in excess of 30 m, the accuracy
declines by 0.15 mm/m.
Use as Intended
The device is intended for measuring distances
as well as for the calculation of areas and vol-
umes. The measured values determined by the
device may not be used to control or trigger
other equipment, machinery or systems. The
device is not suitable for operation in hazardous
areas.
For damage caused by usage other then
intended, the user is responsible.
Display Symbols
1 Laser, switched on
2 Measuring level (front/rear)
3 Information
4 Min/max. indication
5 Pythagoras
6 Automatic release/timer
7 Area/volume
8 Battey status display
9 Unit of measure
10 Displays for intermediate values
11 Main display
Keypad/Pushbuttons
12 On/Off switch, distance measurement,
tracking
13 Add button for calculations
14 Measuring Functions
15 Change measuring level
16 Minus button for calculations
17 Timer
18 Clear/off
19 Type plate
Laser distance meter WDM 61
Order number 0714 640 760
Measuring range 0.05 m – 60 m*
Measuring accuracy, typ. ± 1.5 mm**
Smallest display unit 1 mm
Laser point Ø in 10/50 m 6/30 mm
Automatic shut-off
Illumination/laser/device
20 s/60 s/
180 s
Automatic release/timer 5 s – 60 s
Batteries Micro/LR03
2 x 1.5 V
Battery operating life 4 000 distance
measurements
Protection class (IEC60529) IP 54
Storage temperature 25 ... +70 °C
Operating temperature ±0 ... +40 °C
Weight, approx. 0.1 kg
The symbols on the device have the following meaning:
Laser irradiation
Do not look into the beam
Laser class 2
according to IEC 60825-1: 2007
Max. power output: <1mW
Wavelength: 620 – 690 nm
WDM 61.book Seite 14 Mittwoch, 28. Mai 2008 8:08 08