Attempting to jump start a battery or batteries on an Aviara boat,
regardless of battery brand, from a vehicle or another boat can cause
an overload to the boat’s electrical system, resulting in significant
damage to the electrical system. This is not covered under warranty.
Ignition Start-Stop
Models
All
Location
The ignition key slots are located below the throttles.
Operation
Insert the keys into the key slots. Turn the keys ON. Never start
the engine without having first run the blower for at least four (4)
minutes on stern drive or generator equipped models.
Troubleshooting
If the keys will not turn after being inserted in the key slots, they
are likely to be the wrong keys.
If the keys turn but no electrical power occurs, check the
voltmeter for a reading. If it is lower than 10.5 volts or does
not register, the batteries require recharging. You may also
temporarily use the COMBINE function on the battery
switches. If there is no power at the batteries, the 11” display
will not activate when the key switch is turned on. Using the
COMBINE function when the batteries have power enables
the engines to temporarily use power transferred from the
House batteries to start. Once the boat is running, turn OFF
the COMBINE function. Batteries will recharge automatically
when the boat is running.