This quick start guide helps in completing the installation of COSEC DOOR Controller hardware components.
Differentiate between PANEL DOOR and DIRECT DOOR configurations and their functionalities.
Lists options supported by the COSEC PANEL DOOR Controller.
Lists options supported by the COSEC DIRECT DOOR Controller.
Details on reader interfaces, door relay, exit support, and auxiliary ports.
Understanding the communication methods for PANEL and DIRECT DOORS.
Design considerations for wall mounting without additional enclosures.
Confirm all components are present and undamaged after unpacking.
Recommendations for choosing an optimal and safe location for the controller.
Connecting the controller to the COSEC PANEL for power supply.
Connecting an external 12VDC adapter to power the controller.
Connecting the Matrix PSBB power supply with battery backup.
Illustrates a standard installation setup for the COSEC DOOR unit.
Details on NO, COM, NC, +12VDC terminals and locking device output.
Importance of door closers and supervision of door contacts for alarms.
Connecting an external 12V/24V power supply for higher capacity locks.
Information on the controller's input capacity and supervision with end-of-line resistors.
Default input assignments for door contact and request-to-exit.
Details on the controller's support for internal and external readers via Wiegand/Serial.
Color-coded conductor connections for HID R10/RW100 Prox readers.
Connection diagrams for serial and Wiegand readers.
Guide for connecting external serial readers to the COSEC DOOR terminal strip.
Visual guide showing terminal connections for external reader options.
Wiring diagram for connecting an external serial reader.
Wiring diagram for connecting an external Wiegand reader.
How to link multiple PANEL DOORS using the RS-485 bus.
Location and function of the end-of-line resistor for RS-485 bus.
Using DIP switches to set the controller's physical RS485 address.
Connecting the controller via Ethernet for DIRECT or PANEL door connectivity.
Steps for installing the mounting plate and attaching the controller securely.
Steps to power up the controller and observe initial boot display information.
DIRECT DOORS have default IPs; engineers must configure them on the network.
How to access administrative functions via the keypad and default password.
Steps to change IP address, Subnet Mask, and Gateway settings.
Connecting the controller and PC to an Ethernet hub using patch cables.
Connecting PC and controller directly using a crossover/straight cable.
How PANEL DOORs get IP addresses assigned by the PANEL.
Details on power supply connections and terminal polarity.
Connections for auxiliary inputs/outputs and relay functions.
Terminal assignments for external reader connections.
Connections for RS-485 communication and loop in/out.