436 Matrix ETERNITY NE System Manual
To change CPT-related Timers
• Click the System Timers and Counts link to open the page.
•Go to Call Progress Tones.
• Change the values of the CPT-related Timers as desired.
• Click Submit to save changes.
CPTG Region Codes
CPTG
Region
Code
Region
Dial tone 1 Dial Tone 2 Ring Back Tone Busy Tone
Freq.
Cadence
(sec)
Freq.
Cadence
(sec)
Freq.
Cadence
(sec)
Freq.
Cadence
(sec)
1 Region1 440 Continuous 350+440 Continuous 350+440 0.4on 0.2off
0.4on 2.0off
440 0.75on 0.75off
2 Region2 400 Continuous 400 Continuous 400 0.6on 0.2off
0.2on 2.0off
400 0.5on 0.5off
3 Region3 350+440 Continuous 350+440 Continuous 440+480 2.0on 4.0off 480+620 0.5on 0.5off
4 Argentina 425 Continuous 425 Continuous 425 1.0on 4.0 off 425 0.3on 0.2off
5 Australia 425*25 Continuous 425*25 Continuous 400*25 .4on .2off
.4on 2.0off
425 0.375on
0.375off
6 Brazil 425 Continuous 425 Continuous 425 1.0on 4.0 off 425 0.25on 0.25off
7 Canada 350+440 Continuous 350+440 Continuous 440+480 2.0on 4.0off 480+620 0.5on 0.5off
8 China 450 Continuous 450 Continuous 450 1.0on 4.0off 450 0.35 on
0.36off
9 Egypt 425*50 Continuous 425*50 Continuous 425*50 2.0on 1.0off 425*50 1.0on 4.0off
10 France 440 Continuous 440 Continuous 440 1.5on 3.5off 440 0.5on 0.5off