Maintenance and care
65
KUNDENDIENST
service@matrix-direct.net
DE
+49 (0) 1806/841090
Setting the zero position
1. Set the saw head to 0° on the vertical angle
scale
22
.
2. Set the angle metre up against it.
3. Turn the fine adjustment for the vertical
angle
21
in or out
until the saw blade is at a
90°angle to the tabletop.
4. Tighten the counter nut for the fine
adjustment for the vertical angle.
Setting the 45° position
1. Set the saw head to 4.
2. Apply the angle metre as shown in the
adjacent figure
(180°–135° = 45° = angle to be set).
3. Turn the fine adjustment for the vertical
angle
21
in or out
until the saw blade is at a
45° angle to the tabletop.
4. Tighten the counter nut for the fine
adjustment for the vertical angle.
Maintenance and care
WARNING!
Risk of injury: Accidentally starting the saw can cause severe injury.
Always remove the plug from the socket before performing maintenance
and servicing.
WARNING!
Risk of injury: Improperly maintaining the saw can cause severe injury.
Wear suitable protective gloves.
NOTICE!
Risk of damage: Improper maintenance and servicing of the saw can damage it.
Always keep the vents of the saw clean and free of blockages.
Make sure that no water penetrates the saw.