242 Matrix SATATYA Devices Manual
Select the desired Camera from the drop-down list.
Configure the parameters of Alarm, COSEC, Manual, Scheduled Recording as well as Adaptive Recording as
described below:
Alarm Recording
Pre-Record: Set the time in seconds for pre-alarm event recordings before the actual recording begins on an alarm
event. Default pre-recording time is 5 seconds and the configurable range is from 0-15 second.
Post-Record: Set the time in seconds for post-alarm event recordings for the specified channel. Specify the
duration in seconds as per the site requirements. The configurable range is from 10-300 second.
COSEC Recording
Enable Pre-Record: Select the check box to enable pre-recording in COSEC Recording.
Pre-Record: Set the time in seconds for pre-event recording before the actual recording begins on a COSEC
event. Default pre-recording time is 5 seconds and the configurable range is from 0-15 second.
Manual Recording
Select the check box to enable the manual recording for the selected camera. If disabled, manual recording will not
be allowed.

Table of Contents