9.02
TI013G0008
PROBLEM CAUSE SOLUTION
C. Oil
Excessive oil consumption;
the level lowers too quickly; oil
is detected within the network.
The air-oil separator lter is
clogged.
Replace the lter.
(See chapter 7)
D. Temperature
The compressor stops due to
its own over-heating.
The radiator or the lter of
the cooling air is dirty; the
environmental temperature is
excessive for the compressor
operation.
Verify the cause and remove
the problem.
(See chapter 7)
The compressor stops due to
the over-heating of the motor.
Excessive working pressure. Verify the setting and re-set to
the design value for the machi-
ne.
(See chapter 7)
The main motor cooling is
insuf cient; the cooling air is
either too hot or too little.
Verify the environmental con-
ditions and the condition of the
ltering panel.
(See chapter 3 and 7)
E. NOISE LEVEL
Belts are noisy.
Belts are not tightened enou-
gh.
Correcly tighten the belts.
(see chapter 7).
Troubleshooting

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mattei BLADE Series and is the answer not in the manual?

Mattei BLADE Series Specifications

General IconGeneral
SeriesBLADE
Voltage380-480V, 50/60Hz
CoolingAir-cooled
DriveDirect Drive
DimensionsVaries by model
WeightVaries by model
Control SystemElectronic Controller (various options available)

Related product manuals