Periodic maintenance should be carried out by the user, at least once a month.This should
be done after the clean-up and daily maintenance has been completed.
After adding 500 gram of a decalcifying substance, let the machine wash for 30 minutes.
This way the machine will clean the tank itself. When the machine is finished, drain the
filthy water and let the machine fill up with clean water again. After it has been heated,
repeat the process without adding any additive substances. When the machine finishes
again, let the filthy water drain again, and after this the machine is ready for use once
again.
Make sure you check that the rinsing and washing arms are not blocked by any dirt,
scraps or calcium. When the nozzles in the arms are blocked, you can remove the
washing and rinsing arm and disassemble them. Properly clean them with pressure air,
pressure water, or any other means that will not harm the parts.
If the device is not being used for a longer period of time, you must drain the water left
inside the boiler. For this purpose, let the water drain out after opening the tap (boiler tank
tap) at the lower part of the boiler’s body (see the picture above for reference).
Otherwise water staying inside too long, may harm the machine and cause other trouble.
Be aware that water in the boiler is very hot when the machine has been used, make sure
you give it several hours to cool down, before draining it.
User Responsibilities
The power network of the facility where the machine will be connected should be
installed by the user complying with “indoor electrical installation” regulations.
We advise you to let a certified electrician do this. The manufacturer/importer will
not take responisibility for any consequences of current leakage from the
machine, electrical shocks, failure, or faults inside and outside the machine,
possibly caused by the main power supply of the facility.