1
INSTRUCTION MANUAL
(For Professional Use Only)
ST302PRO
Pro Series Spray Gun
DO NOT USE EQUIPMENT BEFORE READING THIS MANUAL
This manual contains important warnings and instructions.
Please read these instructions carefully and keep for your reference.
Maximst 2023

Other manuals for MaxiMist Pro Series

Question and Answer IconNeed help?

Do you have a question about the MaxiMist Pro Series and is the answer not in the manual?

MaxiMist Pro Series Specifications

General IconGeneral
BrandMaxiMist
ModelPro Series
CategoryPaint Sprayer
LanguageEnglish

Summary

General Safety Information

Safety Warnings and Precautions

Explains safety symbols (DANGER, WARNING, CAUTION) and lists precautions for fire, explosion, hazardous vapors, ventilation, and static electricity.

Operational Safety and Grounding

Details operational safety tips like avoiding tipping and essential grounding instructions for safe use.

Introduction

System Overview

Explains the components and working principle of the MaxiMist HVLP spray tanning system.

Spray Pattern Adjustment

Details how to adjust the air cap for different spray patterns (horizontal, vertical, round).

Spray Gun Controls

Familiarizes users with the main controls of the ST302PRO spray gun: air cap, flow screw, locking ring.

Preparing for Spray Tanning

Outlines the necessary preparation for clients, environment, and solution for optimal results.

Using Your ST302 Spray Gun

Spray Gun Operation and Technique

Guides on how to operate the spray gun, adjust flow, and achieve the correct spray pattern.

Practice and Pattern Adjustment

Provides step-by-step practice instructions for setting the spray pattern and flow for optimal results.

Operational Cautions and Notes

Highlights important cautions regarding trigger lock and notes on cleaning between applications.

Troubleshooting

No Solution Output

Addresses issues where no solution comes out despite air supply, checking cup pressurization and components.

Continuous Airflow

Explains why air continually flows through the air cap even when the trigger is not pulled.

Excessive Overspray

Offers solutions for excessive overspray by adjusting gun distance and fluid flow settings.

Spray Gun Maintenance and Cleaning

Daily and End-of-Session Cleaning

Details procedures for cleaning the spray gun after use, including using cleaner and hot water.

Fluid Tip and Needle Assembly Care

Explains how to remove, clean, and reassemble the fluid tip, nozzle, and needle assembly.

Cup Gasket and Needle Packing

Describes the function of cup gasket and needle packing and when they may need replacement.

ST302PRO Diagram and Parts List

Spray Gun Component Diagram

Illustrates the ST302PRO spray gun with numbered parts for easy identification.

Parts List and Descriptions

Provides a detailed list of all parts with their corresponding numbers and descriptions.

Warranty and Technical Support

Technical Support Contact Information

Provides contact details for MaxiMist technical support, including phone, fax, and email.

One Year Limited Warranty

Details the terms and conditions of the one-year limited warranty for the ST302Pro Spray Gun.

Warranty Exclusions and Limitations

Lists what is not covered by the warranty, including misuse, neglect, and normal wear and tear.

Spray Gun for Optimum Results

Achieving the Correct Spray Pattern

Guides on how to adjust the spray gun to achieve a consistent 4-inch-wide spray pattern.

Application Technique

Explains the easiest way to achieve optimal results, including setup and practice steps.

Spray Pattern Width Measurement

Illustrates how spray pattern width is measured from the widest point on each outside edge.

Troubleshooting Spray Gun Issues

Solution Spit or No Spray

Fixes for spitting or no solution output by adjusting flow knob setting for solution thickness.

Excessive Overspray and Fogging

Solutions for overspray by checking flow control settings and gun distance from skin.

Solution Running or Dripping

Addresses running solution due to wide flow control or oversaturation, advising quick movement.