EXIT PWR
ALARM
POWER /
SOLAR IN
BATTERY
INPUT
OPENING CLOSING
CLOSINGOPENING
ERD
OBD PORT
BLACK BOX
PROGRAMMING
SOLAR MODE
PROGRAM
MOTOR
OVER
LOAD
ERD
MOTOR
OVER
LOAD
MAX
OFF
MAX
SENSE
MAX
SENSE
BATTERY
BACKUP MODE
ERD SENSITIVITY
MOTION CONTROL
OPEN
GATE SPEED
MAG
LOCK
UL
ENTRAP
PRIMARY/
SECONDARY
LINK
STOP CLOSE
MOTOR
INPUTS
CLOSE
TIMER
MAGLOCK
DELAY
JOG
BATTERY
TEST
INPUT
ERROR
BATTERY
BATTERY
IN USE
REPLACE
BATTERY
LEAVE
CLOSED
LEAVE
OPEN
OPEN
1 TIME
BATTERY VOLTAGE
E F1/2
RESET /
MANUAL
RELEASE
ID
PLUG
LINK
OK
MODULE
PORT
MOTOR
POSITION
INPUTS
SLIDER
LIMIT
SWING
LIMIT
GND
OPEN ONLY NC
OPEN ONLY 10K
PHOTO CLS NC
OPEN/CLS NC
GND
12VDC OUT
GND
GND
GND
GND
GND
GND
JOG RIGHT
JOG LEFT
TAMPER IN
TAMPER NO
GATE DISABLE
MANUAL RELEASE
KEYPAD / CARD
GND
(-)
(+)
GND
GND
MAX OPEN
FIRE DEPT
RADIO GND
RADIO SIGNAL
STRIKE
CLOSE
COM
COM
STOP
OPEN
CLS ONLY 10K
OPEN/CLS 10K
12VDC OUT
NO
COM
NC
ID PLUG
ERROR
24VDC OUTPUT
12VDC OUTPUT
GND
GND
GND
LOOP PWR
OFF
PRIMARY
LEFT
ON/OFF
BATTERY
RIGHT
SECONDARY
ON
QUICK
CLOSE
OPEN
LEFT
OPEN
RIGHT
GATE
OFF
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
MIN MIN
MAX MAX
ON
OFF 2.5 sec
1.5 sec
FAULTS
OPERATOR
MATRIX III
OFF
OFF
3
1
14
16
MIN
16
MIN
12
9
7
3
1
14 12
9
7
UL SENSOR N.C.UL SENSOR 10K
POWER
MODE A MODE B
EXIT LOOP
LOOP
LOOP
CENTER
SAFETY
GATE OPEN
COM
GATE CLOSED
MIN
MATRIX III
SWING / SLIDE
EXIT PWR
ALARM
POWER /
SOLAR IN
BATTERY
INPUT
OPENING CLOSING
CLO
OPENING
ERD
OBD PORT
BLACK BOX
PROGRAMMING
SOLAR MODE
PROGRAM
MOTOR
OVER
LOAD
E
M
O
L
MAX
SENSE
MAX
SENSE
BATTERY
BACKUP MODE
ERD SENSITIVITY
MOTION CONTROL
OPEN
GATE SPEED
PRIMARY/
SECONDARY
LINK
STOP CLO
BATTERY
TEST
INPUT
ERROR
BATTERY
BATTERY
IN USE
REPLACE
BATTERY
LEAVE
CLOSED
LEAVE
OPEN
OPEN
1 TIME
BATTERY VOLTAGE
E F1/2
RESET /
MANUAL
RELEASE
ID
PLUG
LINK
OK
MODULE
PORT
GND
GND
GND
MANUAL RELEASE
KEYPAD / CARD
GND
(-)
(+)
GND
GND
MAX OPEN
FIRE DEPT
RADIO GND
RADIO SIGNAL
STRIKE
STOP
OPEN
ID PLUG
ERROR
24VDC OUTPUT
12VDC OUTPUT
GND
GND
GND
LOOP PWR
OFF
PRIMARY SECONDARY
ON
QUICK
CLOSE
OPEN
LEFT
GATE
OFF
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
MIN MIN
MAX MAX
ON
FAULTS
OPERATOR
OFF
OFF
3
1
14
16
MIN
16
MIN
12
9
7
3
1
14 12
9
7
POWER
MODE A MODE B
EXIT LOOP
LOOP
LOOP
CENTER
SAFETY
MATRIX III
SWING / SLIDE
-AXIMUM#ONTROLSOFFERSASOLARPOWERENCLOSURETOPOWERTHECONTROLBOXANDSOLARPANEL3OLDSEPARATELY
-OUNTSOLARPOWERENCLOSUREUNDERNEATHCONTROLBOX#ONNECTSOLARADAPTERCABLETO
DO NOTCONNECT!#POWERTOTHETOROIDBOX
LOADBATTERYSOLAR
+
-
+
-
+
-
Solar Regulator Terminal
Solar Enclosure
#ONNECTTO
POWER/
SOLAR IN
NOTE:#OVERSOLARPANEL
FROMSUNLIGHTBEFORE
WIRINGTOPREVENTASHOCK
FROMOCCURRING
5SEINSULATEDTOOLSANDAVOID
PLACINGMETALOBJECTSNEARTHE
BATTERIES
Pos + Red
Neg - Black
Polarity Matters!
Solar
Adapter
cable
Properly Ground Enclosure.
24 V Batteries
Use AGM battery type.
12 Volt
Batteries wired in series
12 Volt
"ATTERIESSHOULDBEINA
WELLVENTILATEDENCLOSURE
OROVERHEATINGWILLOCCUR
ANDREDUCEBATTERYLIFE
DANGER
HAZARDOUS CURRENT
.%6%2TOUCH
POSITIVEAND
NEGATIVEBATTERY
CABLESTOGETHER
35 Amp/Hr batteries
Solar Panel
Regulator Specs:
24 V MAX - 20 Amp
J
OG
GATE
OPEN / CLOSE
RESET
AL
AR
M
Control Box
Solar Enclosure
L
E
LEF
QUICK
L
E
PEN
FF
N
ATE
PEN
M
FF
TI
N
NTR
M
T
P
ITI
NPUT
LIDER
L
SWING
SOLAR MODE
OFF ON
5SEflexibleCONDUITTOCONNECT
SOLARENCLOSURETOCONTROLBOX
NOTPROVIDED
4URN3/,!2-/$%ON
-OUNTSOLARENCLOSUREASCLOSEASPOSSIBLETO
CONTROLBOXUSINGEXISTINGMOUNTINGHOLES
4 Mounting Holes
-OUNTINGHARDWARE
NOTPROVIDED
Back of Solar Enclosure
3
5,3TANDARD-!802/02/&02/-ATRIX))))NSTALL6ERSIONB
QRVKQPCNUQNCTRQYGT