Maxitrol GV60 - Advanced System Operation Features; Operational Safeguards and Modes

Maxitrol GV60
57 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8
Low Battery Receiver
When the receiver battery power is low, the GV60 system shuts off the fire and pilot.
Five Day Shut Off
(CSA version)
The system shuts off the fire and pilot if there is no change in flame height for 5 days.
Backup Batteries
If the mains power should fail, the receiver automatically goes to battery power for all functions except the light and fan.
Second Thermocouple Shut Off
Second Thermocouple Option: The system shuts off the fire when the main burner does not completely ignite
approximately 20 seconds after ignition or after pushing the large flame button.
NOTE: If there is a failure due to the second thermocouple not receiving a signal, there is a 2-minute waiting period prior to
the next ignition sequence. This is to allow for the gas in the system to dissipate.
GV60 System Features