EasyManua.ls Logo

Maxton UC1A - COIL SPECIFICATIONS

Maxton UC1A
102 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1728 Orbit Way - Minden, Nevada 89423 P: 775-782-1700 F: 775-782-1701 info@maxtonvalve.com www.maxtonvalve.com
81
\\SERVER\CATALOG2019\2019CatalogRev2
Current (AMPS) measured when coil is tested on a fully assembled control plate with C-Frame installed.
Part No. Coil Color
Lead Wires
Coil Wire
Size
(AWG)
Voltage
OHMS ± 10%
Current (AMPS)
± 10%
Length (inches)
+2”, -0”
DC Resistance
At 25° C
With Leads
DC
AC
2082B0
(Dual Use)
Red 96 26
115 VAC
24.5
--
.66
24 VDC
.9 -
288980
(Dual Use)
Black 5 26
115 VAC
24.5
-- .66
24 VDC
.9 -
208000
Green 96 29 230 VAC 116 -- .230
208100
Black 96 32 115 VDC 512 .22 --
208300
Black 96 22 12 VDC 5.20 2.19 --
2080A0
Blue 96 28 185 VAC 78.2 -- .220
2082A0
(Dual Voltage)
Red 96
Yellow 23 12 VDC
4.4 2.59 --
Red 27 120 VAC
24.2 -- .650
Black N/A Common --
-- --
Set of 4 # 29082B* Set of 4 # 290800*
208100
208300
2080A0
2082A0**
115 VAC/24 VDC
Ea. # 2082B0
230 VAC
Ea. # 208000
115 VDC
12 VDC
185 VAC
12 VDC/120 VAC
288980
24 VDC
Use with EMV10
Series Valves Only
* Part # 29082B AND # 290800 COME IN SETS OF 4 WITH MULTI-COLORED LEAD WIRES. COLORS ARE RED, YELLOW, ORANGE AND BLUE.
ALL OTHERS ARE BLACK UNLESS OTHERWISE NOTED
** DESIGNED FOR USE WITH THE DOWN LEVELING SOLENOID FOR EMERGENCY (BATTERY BACKUP) LOWERING. 3-WIRE COLOR CODED
COIL SPECIFICATIONS