CONTROL SYSTEM
01–40–40
NEUTRAL SWITCH FUNCTION [LF]
E5U014017640N01
• The neutral switch detects the neutral position of the gearshift lever.
End Of Sie
NEUTRAL SWITCH CONSTRUCTION/OPERATION [LF]
E5U014017640N02
•
When the shift lever is in the neutral position, the contact closes (ON) and the PCM detects a voltage of 0 V. When
the shift lever is not in the neutral position, the contact opens (OFF) and the PCM detects a voltage of 12 V.
End Of Sie
CLUTCH PEDAL POSITION (CPP) SWITCH FUNCTION [LF]
E5U014018660N01
• This switch determines whether the engine is under a load condition (condition in which the engine output is
transmitted to the powertrain) or under a no-load condition (condition in which the engine output is not
transmitted to the powertrain).
• Detects the clutch engagement condition.
End Of Sie
CLUTCH PEDAL POSITION (CPP) SWITCH CONSTRUCTION/OPERATION [LF]
E5U014018660N02
• When the clutch pedal is depressed, the contact closes (ON) and the PCM detects a voltage of 0 V. When the
clutch pedal is not depressed, the contact opens (OFF) the PCM detects a voltage of 12 V.
End Of Sie
NEUTRAL SWITCH
PUSH ON
OTHER THEN
NEUTRAL (OFF)
NEUTRAL (ON)
NEUTRAL (ON)
EXCEPT ABOVE
PCM
NO LOAD
LOAD
CPU
C3U0140S030
CPP SWITCH
PUSH OFF
PCM
CLUTCH PEDAL NOT
DEPRESSED (OFF)
CLUTCH PEDAL NOT
DEPRESSED (OFF)
CLUTCH PEDAL
DEPRESSED (ON)
CLUTCH PEDAL
DEPRESSED (ON)
NO LOAD
LOAD
CPU
C3U0140S031