INSTRUMENTATION/DRIVER INFO.
09–22–9
09–22
PID/Data Monitor and Record
• The PID/data monitoring items for the instrument cluster is as shown in following the table:
Monitor item table
—: Not applicable
Odometer-data Transfer
• If all the following conditions are met, the odometer data (total traveled distance) in the previous instrument
cluster is automatically transferred to a new instrument cluster during the configuration. If any of the conditions
are not met, odometer-data transfer cannot be performed.
Previous instrument cluster
— No malfunction (Configuration data can be read using the WDS or equivalent.)
New instrument cluster
— Odometer display is less than 100 km
— Odometer has no malfunction
Note
• If the odometer display of a new instrument cluster is 100 km or more, an error is displayed on the WDS
after the configuration is completed. In this case, the configuration data for items other than the odometer
are transferred to a new instrument cluster.
End Of Sie
LCD
SPEEDOMETER
TACHOMETER
BUZZER
WARNING AND
INDICATOR LIGHT
FUEL
GAUGE
WATER
TEMPERATURE
GAUGE
ILLUMINATION
LIGHT BULB
INSTRUMENT CLUSTER
MICROCOMPUTER
OIL PRESSURE
GAUGE
E5U922ZS5005
Monitor item
Input-output signal/part
name
Unit/State Terminal
IC_DTC_CNT Number of continuous DTCs — —
IC_ECT Water temperature gauge °F °C1J, 1L
IC_NUMKEYS
Number of key ID numbers
registered with the vehicle
——
IC_ODO_CNT Odometer m
1J, 1LIC_SPDMTR Speedometer MPH KPH
IC_TACHO Tachometer RPM
IC_VPWR Power supply voltage V 1C