Diagnostic procedure
STEP INSPECTION ACTION
Yes Go to Step 11.
1
INSPECT HORN AND HAZARD WARNING
LIGHT OPERATION DURING ON-BOARD
DIAGNOSIS
• Do all of the following items work during on-
board diagnostic function operation?
Hazard warning lights flash.
Horns sounds intermittently.
Trunk lid opens.
No Go to the next step.
Yes Go to Step 5.
2
INSPECT HAZARD WARNING LIGHT
OPERATION DURING ON-BOARD DIAGNOSIS
• Do the hazard warning lights flash during on-
board diagnostic function operation?
No Go to the next step.
Yes Go to the next step.
3
INSPECT HAZARD WARNING LIGHT CIRCUIT
• Do the hazard warning lights flash when hazard
warning switch is on?
No Inspect the hazard warning light circuit.
Yes
Reinspect the malfunction symptoms,
then repeat from Step 1 if malfunction
recurs.
*4
INSPECT IF MALFUNCTION IS IN WIRING
HARNESS (BETWEEN KEYLESS CONTROL
MODULE AND FLASHER CONTROL MODULE)
OR KEYLESS CONTROL MODULE
• Measure the voltage at keyless control module
connector terminal 2I during on-board diagnostic
function operation.
When hazard warning lights flashed:
Alternates between B+ and below 1.0 V
• Is the voltage as above?
No
• Inspect the wiring harness
between the keyless control
module and flasher control
module.
If the wiring harness is
normal, replace the
keyless control module
and reprogram the
transmitter ID code, then
go to Step 14.
If the wiring harness is
malfunctioning, repair the
wiring harness, then go to
Step 14.
5 Yes Go to Step 8.