INSPECT COMMUNICATION
CIRCUIT (OUTPUT) FOR
CONTINUITY
• Turn the ignition switch to the LOCK
position.
• Disconnect the keyless control
module connector.
• Is there continuity between coil
connector terminal A and keyless
control module connector terminal
3F?
No Go to the next step.
Yes
Replace the keyless control module and perform
procedures for when replacing the keyless control
module only.
(See KEYLESS CONTROL MODULE
REMOVAL/INSTALLATION .)
(See IMMOBILIZER SYSTEM COMPONENT
REPLACEMENT/KEY ADDITION AND
CLEARING .)
10
INSPECT COIL OUTPUT SIGNAL
CIRCUIT
• Measure the resistance between
keyless control module connector
terminal 3F and ground.
Is the resistance 10 kilohms or
more ?
No Repair the wiring harness.