Diagnostic Procedure
STEP INSPECTION ACTION
Yes
Replace the coil, then go to the next step.
(See COIL REMOVAL/INSTALLATION .)
1
VERIFY WHETHER KEY IS VALID OR
NOT
• Using another registered key, turn the
ignition switch to the ON position.
• If there is not another registered key, register
an additional key using the WDS or
equivalent and turn the ignition key to the
ON position using the registered key.
(See IMMOBILIZER SYSTEM
COMPONENT REPLACEMENT/KEY
ADDITION AND CLEARING .)
• Is the DTC displayed again?
SECURITY LIGHT: 14
WDS or equivalent: B1602/P1260
No
• Dispose of the malfunctioning key.
• Register a new key if necessary.
(See IMMOBILIZER SYSTEM
COMPONENT
REPLACEMENT/KEY ADDITION
AND CLEARING .)
Yes
Replace the keyless control module and
perform procedures for when replacing the
keyless control module only.
(See KEYLESS CONTROL MODULE
REMOVAL/INSTALLATION .)
(See IMMOBILIZER SYSTEM
COMPONENT REPLACEMENT/KEY
ADDITION AND CLEARING .)
2
INSPECT KEYLESS CONTROL MODULE
• Using another registered key, turn the
ignition switch to the ON position.
• Is the DTC displayed again?
SECURITY LIGHT: 14
WDS or equivalent: B1602/P1260
No DTC troubleshooting completed.