McCain ATC NEMA Controller – User Manual
Version 1.0
APPENDIX E: CONNECTOR’S DETAILS, OPTIONAL CONNECTOR BOXES
The ATC NEMA controller is a TS2 Type 1 controller that can be converted to a TS2 Type two controller by
adding an optional connector box in order to support the functionality of the A, B, C connectors of the TS1
standard plus the special configuration D connector.
Currently there are two optional boxes, the Standard McCain connector Box and the Traconex compatible box.
The only one difference between them is the special configuration D connector.
Below is listed the pin assignment for each connector.
Connector A
It is a round keyed male pin MilSpec connector of 55 pins with the following pin assignment:
Connector A
Pin Function I/O
A Fault Monitor --
B +24VDC (EXTERNAL) O
C Voltage Monitor O
D Phase 1 Red O
E Phase 1 Don't Walk O
F Phase 2 Red O
G Phase 2 Don't Walk O
H Phase 2 Pedestrian Clear O
J Phase 2 Walk O
K Phase 2 Vehicle Detector I
L Phase 2 Pedestrian Detector I
M Phase 2 Hold I
N Stop Time, Ring 1 I
P Inh Max Term, Ring 1 I
R External Start I
S Interval Advance I
T Indicator Lamp Control I
U 110VAC Neutral AC -
V 110VAC/Chassis Ground Cgnd
W 2070N DC GND, Logic Ground Lgnd
X Flashing Logic Out O
Y Coded Stat Bit C Ring 1 O
Z Phase 1 Yellow O
a Phase 1 Pedestrian Clear O
b Phase 2 Yellow O
c Phase 2 Green O
d Phase 2 Check O
e Phase 2 On O
f Phase 1 Vehicle Detector I
g Phase 1 Pedestrian Detector I
h Phase 1 Hold I
i Force Off Ring 1 I
j Min Recall All Phases I
k Manual Control Enable I
m Call Non-Actuated I I
n Test Input A I