Connector A
It is a round keyed male pin MilSpec connector of 55 pins with the following pin assignment:
Connector A
Pin Function I/O
A Fault Monitor --
B +24VDC (EXTERNAL) O
C Voltage Monitor O
D Phase 1 Red O
E Phase 1 Don't Walk O
F Phase 2 Red O
G Phase 2 Don't Walk O
H Phase 2 Pedestrian Clear O
J Phase 2 Walk O
K Phase 2 Vehicle Detector I
L Phase 2 Pedestrian Detector I
M Phase 2 Hold I
N Stop Time, Ring 1 I
P Inh Max Term, Ring 1 I
R External Start I
S Interval Advance I
T Indicator Lamp Control I
U 110VAC Neutral AC -
V 110VAC/Chassis Ground Cgnd
W 2070N DC GND, Logic Ground Lgnd
X Flashing Logic Out O
Y Coded Stat Bit C Ring 1 O
Z Phase 1 Yellow O
a Phase 1 Pedestrian Clear O
b Phase 2 Yellow O
c Phase 2 Green O
d Phase 2 Check O
e Phase 2 On O
f Phase 1 Vehicle Detector I
g Phase 1 Pedestrian Detector I
h Phase 1 Hold I
i Force Off Ring 1 I
j Min Recall All Phases I
k Manual Control Enable I
m Call Non-Actuated I I
n Test Input A I