Page 9For technical questions, please call 1-888-866-5797.Items 57572 57567
SAFETYOPERATIONMAINTENANCE INSTALLATION
Emergency Depressurization
If it is necessary to quickly depressurize the Compressor, turn the Power Switch OFF.
Then, pull on the ring on the Safety Valve to quickly release stored air pressure.
Automatic Shut off System
This unit is equipped with Thermal Overload Protection.
1. If the Compressor automatically shuts off
before reaching its normal cutoff pressure:
a. Turn it off and unplug it for 15 minutes.
b. Plug it back in.
c. Turn unit on and resume operation.
2. Possible causes of repeated automatic
shut off of the compressor are:
a. Using an extension cord that
is too long or narrow;
b. An air leak or open hose causing the compressor
to cycle too often and build up heat.
c. Turning Air Compressor off and
on again too quickly.
3. Correct any issues before further use to
avoid damage to the compressor.
Maintenance and Servicing
Procedures not specifically explained in this manual must
be performed only by a qualified technician.
TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION:
Turn the Power Switch “OFF” and unplug the Compressor from its electrical outlet
before performing any inspection, maintenance, or cleaning procedures.
TO PREVENT SERIOUS INJURY FROM COMPRESSOR FAILURE:
Do not use damaged equipment. If abnormal noise or vibration occurs,
have the problem corrected before further use.
Cleaning, Maintenance, and Lubrication
1. BEFORE EACH USE, inspect the general
condition of the air compressor. Check for:
loose hardware,
misalignment or binding of moving parts,
cracked or broken parts,
damaged electrical wiring, and
any other condition that may
affect its safe operation.
2. AFTER USE, wipe external surfaces of
the compressor with a clean cloth.
3. WARNING! TO PREVENT SERIOUS
INJURY: If the supply cord of this
compressor is damaged, it must be replaced
only by a qualified service technician.