Do you have a question about the mcmurdo 406 EPIRB and is the answer not in the manual?
Brand | mcmurdo |
---|---|
Model | 406 EPIRB |
Category | Marine Equipment |
Language | English |
Details the wall mounting bracket, its material, release mechanism, and siting requirements.
Explains the automatic release mechanism of the float-free enclosure via a Hydrostatic Release Unit (HRU).
Describes the category 2 EPIRB for exposed positions without a HRU, and how to identify it.
Details the ON button function, its protective sliding door, tamper seal, and activation procedure.
Explains the READY button for de-activation and running the built-in self-test procedure.
Describes the sea switch activation, its time delay, and how it interacts with manual controls.
Details the function of the Strobe light and Red lamp for location and status indication.
Instructions for automatic EPIRB activation and operation when a Category 1 vessel sinks.
Procedure for manually releasing and carrying the EPIRB to a liferaft during abandonment.
Step-by-step instructions for detaching the EPIRB from its wall mounting bracket.
Instructions for manually releasing the EPIRB from its protective float-free enclosure.
Guide to manually activating the EPIRB in imminent danger when the vessel is not sinking.
Steps to reset the EPIRB to its 'ready' state after accidental activation or end of emergency.
Information on when the EPIRB battery needs replacement based on usage or expiry date.
Procedures for re-installing the EPIRB into its wall bracket or enclosure after use or testing.
Instructions on how to contact rescue authorities to report a false EPIRB alarm.
Procedure for de-activating a mistakenly activated EPIRB and ensuring it is correctly refitted.
Methods to suppress a faulty EPIRB's signal by removing the antenna or using metal foil.
Guidance on choosing the optimal location for mounting the wall bracket, considering access and interference.
Detailed steps and dimensions for securely mounting the wall bracket using provided fixings.
Instructions for mounting the visual instruction plate next to the EPIRB for emergency operation guidance.
Recommendations for choosing a suitable mounting position for the float-free enclosure, avoiding obstructions.
Steps for mounting the enclosure backplate, including lid removal and checking EPIRB fit.
Guidance on mounting the instruction plate next to the EPIRB, similar to the wall bracket version.
Procedure for marking the Hydrostatic Release Unit (HRU) expiry date on the unit and enclosure.
Instructions for marking the vessel name on the EPIRB and enclosure labels for identification.
Explains the EPIRB's unique identity, country code, and the importance of registration for rescue services.
Details on completing registration forms, online or by mail/fax, and receiving a registration decal.
Instructions for completing and submitting the warranty form to McMurdo for future claims.
Guidance on updating your radio licence to include the EPIRB transmitter.
Procedure for updating registration details when transferring the EPIRB to a new vessel or owner.
Specific registration requirements for Oceania, emphasizing immediate card completion and submission.
Procedure for performing a monthly self-test and visual inspection of the EPIRB and its mounting.
Instructions for replacing the Hydrostatic Release Unit (HRU) in Category 1 enclosures, including expiry checks.
Information on EPIRB battery type, lifespan, and conditions requiring replacement (emergency use, expiry).
Guidance on obtaining servicing for the EPIRB from approved McMurdo service agents.
Notes on special transportation requirements for EPIRBs due to their Lithium battery content.
Details on GMDSS inspections for commercial vessels, checking expiry dates and registration.