EasyManuals Logo

McQuay MWM09J User Manual

McQuay MWM09J
90 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #56 background imageLoading...
Page #56 background image
54
MWM-J_(ii) Performance Data
Model: M5WM25JR - M5LC25CRJ
Heating Mode
ID DB°C
Outdoor WB°C
-9 -6 -5 6 12 15 18
Q (kW) SC (kW) Q (kW) SC (kW) Q (kW) SC (kW) Q (kW) SC (kW) Q (kW) SC (kW) Q (kW) SC (kW) Q (kW) SC (kW)
15 3z.721 3.721 4.211 4.211 4.375 4.375 6.173 6.173 7.154 7.154 7.645 7.645 8.135 8.135
17 3.623 3.623 3.734 3.734 4.282 4.282 6.166 6.166 7.081 7.081 7.575 7.575 8.069 8.069
19 3.526 3.526 3.257 3.257 4.189 4.189 6.158 6.158 7.008 7.008 7.505 7.505 8.003 8.003
21 3.428 3.428 3.108 3.108 4.096 4.096 6.089 6.089 6.934 6.934 7.435 7.435 7.936 7.936
23 3.331 3.331 3.288 3.288 4.003 4.003 5.956 5.956 6.861 6.861 7.366 7.366 7.870 7.870
25 3.233 3.233 3.467 3.467 3.910 3.910 5.824 5.824 6.788 6.788 7.296 7.296 7.804 7.804
27 3.135 3.135 3.647 3.647 3.817 3.817 5.692 5.692 6.715 6.715 7.226 7.226 7.737 7.737
Remark:
AFR: Air ow rate (CFM)
EWB: Entering Wet Bulb Temp. (°C)
EDB: Entering Dry Bulb Temp. (°C)
TC: Total Cooling Capacity (kW)
SHC: Sensible Heat Capacity (kW)
PI: Power Input
Notes:
1. Ratings shown are gross capacities which do not include a deduction for indoor fan motor heat.
2. shows nominal capacities.
3. Direct interpolation is permissible. Do not extrapolate.
4. Unit is able to operate at ambient from 0 °C to 46°C without pressure trip.
Part Number : 0652102C2525

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the McQuay MWM09J and is the answer not in the manual?

McQuay MWM09J Specifications

General IconGeneral
BrandMcQuay
ModelMWM09J
CategoryAir Conditioner
LanguageEnglish

Related product manuals