User's Reference Manual
Interactive Monitor
Data Collection Suspended During Test -
This message indicates that data collection has been
halted temporarily while this command executes.
Disable Descrete Collection First -
This message results when you attempt to change the transfer
blocksize
with
descrete mode collection enabled. Descrete mode collection must be disabled
(default) before the blocksize can be changed.
Dump Mode Canceled -
This message indicates that the MDR-2000
'SD'
command was in effect
and has been canceled by the Interactive Monitor.
Exiting -
This message indicates that the Interactive Monitor session is being terminated. This is a
result
of
entering the
'EXIT'
command or pressing <Control-V>.
Set Xfer Blocksize To 1 First -
This message results when you attempt to enable descrete mode
collection with a transfer blocksize greater than one. The blocksize must be
1 (default value), when
using descrete
mod
e collection.
Value Out
Of
Range -
This message indicates that a number has been entered that is too large. For
example, even though the processor memory can access up to 64K less than this exists
on
the actual
MDR-2000.
If
the actual quantity is exceeded then this message results.
5-21