Drwg. No. 3587
FADINI
meccanica
GB
CONNECTION DIAGRAM
ELECTRONIC PROGRAMMER
FOR SINGLE-PHASE SWINGING GATES
FUSE 1.6A
OUTPUT 24V
TERMINALS 12-13
230V
TRANSFORMER
1
PC BOARD
ON VOLTAGE
Elpro 33 exp
ELPRO 33
INTEGRATED CIRCUIT
for SWING GATES
3
28
27
26
29
30
COMMON. BUTTONS
TERMINALS TO
CONNECT THE PUSH
BUTTONS PULIN 3
COURTESY LAMP
230V - 50Hz
OR FLASHING LAMP 25 W
10 11 12 13
RADIO CONTROL
PLUG-IN CARD
SUPPORT
POWER SUPPLY
24V
CHANNEL 1
CLR ENT
"A" "B"
DISPLAY
PROGRAMMING
BUTTONS
9
ELECTRIC LOCK
CAPACITOR
12.5µF
CAPACITOR
12.5µF
TRANSFORMER
FUSE
630mA
HIGH VOLTAGE
FUSES
6.3A
1
16
N.C. CONTACT
1st P
AIR PHOTOCELLS
SINGLE-PHASE
ELECTRIC
MOTORS
M1
M2
=PHOTOCELL 2nd PAIR=
Internal photocells. N.C.contacts
if obstructed they prevent gates
from opening, reverse gate
direction on closing cycle
N.W.:
to be set by MOD6=0
COMMON
8 2 3 4 5 6 7
2 3 4 5 6 7 8 9 10 11 12 13 14 15
COMMON
N.O. CONTACT OPEN
N.O. CONTACT CLOSE
N.C. CONTACT STOP
RADIO CONTACT
COMMON
24V ac OUTPUT
ELECTRIC LOCK
INDICATOR 24V - 3W max.
24V ac OUTPUT
MAX. LOAD
2 P
AIRS PHOTOCELLS
1 RADIO RECEIVER
N.C. SAFETY
CONTACT
COMMON
FLASHING LAMP
230V - 25W max.
230V SINGLE-PHASE
SUPPLY VOLTAGE
17 18 19 20 21 22 23 24 25
NEUTRAL
LIVE
3 4
3 4
PEDESTRIAN OPENING CONT
A
CT
ANY PULSE HELD ON FOR MORE
THAN 2 SECONDS OPENS ONLY ONE
GATE LEAF; TOW CONSECUTIVE
PULSES OPEN BOTH GATE LEAVES
N.W.:
set by MOD5=1
EXTERNAL TIME CL
OCK INPUT:
A PULSE TO A N.C. COMMAND
SWITCH HELD ON FOR MORE THAN 6
SECONDS. ONCE THE CLOCK TIME
HAS EXPIRED, THE GATES ARE
AUTOMATICALLY CLOSED, AFTER THE
DWELL TIME.
DURING THE TIME CONTROLLED BY
THE CLOCK NO OTHER PULSES eg
OPEN-CLOSE-RADIO PULSES ARE
ACCEPTED
N.W.:
Set by MOD3=1
and
MOD5=0
7 8
RADIO CONT
A
CT:
ALL OPERATIONS OPEN CLOSE
AND REVERSE
N.W.:
set by MOD2=0
Should more pairs of photocells be required than the
recommended quantity, fit an auxiliary transformer
outside the control box.
N.W.: THIS PANEL IS TESTED TO OPERATE GATES
ONLY THROUGH FADINI ACCESSORIES. NO
GUARANTEE FOR ACCESSORIES OF OTHER MAKE
OR SPECIAL APPLICATIONS
24V