coefficient 1 coefficient 1
P12.12
Flux-weake
ning
adjustment
coefficient 2
Flux-weakeni
ng
adjustment
coefficient 2
0~10000 1 1000 ×
P12.13
Flux-weake
ning control
mode
Flux-weakeni
ng control
mode
0: Disable
1: Enable
1 1 ×
P12.14
Cooling fan
control
Fan control
0: Operate automatically
1: Fan operates continually during
power-up
2: Fan operates based on
command
Note: It will keep running for 3
minutes after power-off
1 2 × ×
P12.15
~P12.19
Reserved Reserved
Group P13: Multi-stage reference and simple PLC parameters
P13.00
Multi-stage
reference
property
setting
Multi-stage
reference
property
0: Multi-stage frequency reference
1: Multi-stage closed loop
reference
1 0 ×
P13.01
Multi-stage
reference 1
Multi-stage
reference 1
When it is multi-stage frequency:
0.0%~100.0% corresponds to
“minimum frequency ~ maximum
frequency”
When it is multi-stage closed loop
reference:
-100.0%~100.0% corresponds to
“-10V~+10V”
0.1% 10.0% ×
P13.02
Multi-stage
reference 2
Multi-stage
reference 2
0.1% 20.0% ×
P13.03
Multi-stage
reference 3
Multi-stage
reference 3
0.1% 40.0% ×
P13.04
Multi-stage
reference 4
Multi-stage
reference 4
0.1% 60.0% ×
P13.05
Multi-stage
reference 5
Multi-stage
reference 5
0.1% 80.0% ×
P13.06
Multi-stage
reference 6
Multi-stage
reference 6
0.1% 90.0% ×
P13.07
Multi-stage
reference 7
Multi-stage
reference 7
0.1% 100.0% ×
P13.08
Multi-stage
reference 8
Multi-stage
reference 8
0.1% 10.0% ×
P13.09
Multi-stage
reference 9
Multi-stage
reference 9
0.1% 20.0% ×
P13.10
Multi-stage
reference
10
Multi-stage
reference 10
0.1% 40.0% ×
P13.11
Multi-stage
reference 11
Multi-stage
reference 11
0.1% 60.0% ×
P13.12
Multi-stage Multi-stage
0.1% 80.0% ×