108
time
P14.28
PID
feedback
exceeding
limit
detection
value
PID
feedback
exceeding
limit
detection
value
0.0~100.0% 0.1% 100.0% ×
P14.29
PID
feedback
exceeding
limit
detection
time
PID
feedback
exceeding
limit
detection
time
0.0s~25.0s 0.1s 1.0s ×
Group P15: Communication parameters
P15.00
Protocol
selection
Protocol
selection
0: MODBUS
1: Reserved
1 0 × ×
P15.01
Communica
tion
configuratio
n
Communicati
on
configuration
Unit place of LED: Baud rate
selection
0: 4800BPS
1: 9600BPS
2: 19200BPS
3: 38400BPS
4: 115200BPS
5: 125000BPS
Tens place of LED: Data format
0: 1-8-2-N format, RTU
1: 1-8-1-E format, RTU
2: 1-8-1-O format, RTU
3: 1-7-2-N format, ASCII
4: 1-7-1-E format, ASCII
5: 1-7-1-O format, ASCII
Hundreds place of LED: wiring
mode
0: Direct cabling (232/485)
1: MODEM (232)
1 001 × ×
P15.02
Local
address
Local
address
0~247, 0 is the broadcast address 1 5 × ×
P15.03
Communica
tion timeout
detection
time
Communicati
on timeout
time
0.0~1000.0s
0.1 0.0s × ×
P15.04
Response
delay of the
drive
Response
delay of the
drive
0~1000ms
1 5ms × ×
P15.05
Reserved
function 1
for user
Reserved
function 1 for
user
0~65535
1 0 ×