Function
code
Name
Index-
Sub-index
Value range
Min. unit
Default
value
Menu
mode
Cha
nge
Q
B
deceleration
P97.10
Auto current
limiting level
2061-0Bh
20.0% to 200.0% Ie
0.1%
150.0%
×
×
P97.11
Frequency
decrease rate
during current
limiting
2061-0Ch
0.00 to 99.99 Hz/s
0.01 Hz/s
10.00
Hz/s
×
P97.12
Short-to-
ground
detection upon
power-on
2061-0Dh
0: Disabled
1: Enabled (valid for 7.5
kW and below)
1
1
×
P97.13
Auto reset
attempts
2061-0Eh
0: No function
1 to 100: Auto reset
attempts
Note: No auto reset
function for module
protection, external
device fault and AI
overcurrent fault
1
0
×
×
P97.14
Auto reset
interval
2061-0Fh
2.0 to 20.0 s for each time
0.1 s
5.0 s
×
×
P97.15
First fault type
2061-10h
0: No abnormal records
1: Servo drive overcurrent
during acceleration
(Er.oC1)
2: Servo drive overcurrent
during deceleration
(Er.oC2)
3: Servo drive overcurrent
at constant speed
(Er.oC3)
4: Servo drive overvoltage
during acceleration
1
0
×
*