14 Troubleshooting
Problem Cause Solution
Coffee only runs
drop-by-drop
Grind setting too fine Set the grind to a coarser setting
Clean brewing unit
Descale if necessary
If necessary, run a cleaning
programme
Coffee does not flow Water reservoir not filled
or incorrectly inserted
Fill the water reservoir and en-
sure that it is correctly seated
If necessary open the valve
until water runs out of the ap-
pliance, then re-close valve
Brewing unit obstructed Clean the brewing unit
Grinder does not
grind coffee beans
Beans do not drop into
the grinder (beans are too
oily)
Tap lightly on the bean con-
tainer
Foreign objects in the
grinder
Contact the hotline
Loud grinder noise Foreign objects in the
grinder
Contact the hotline
Bean symbols
are flashing although
the bean container is
filled.
Insufficient quantity of
ground beans in the brew-
ing chamber
Press the button for coffee
dispensing
or brewing
strength
Symbol for the valve
lights up out of
sequence
There is air in the lines
inside the appliance.
if necessary open valve until
water runs out of the appliance
and then re-close the valve.
Clean brewing unit
Not enough milk
froth is formed
during the frothing
process
The nozzle of the steam
pipe is in the wrong posi-
tion
Adjust the nozzle to the proper
position
The steam pipe nozzle is
soiled
Clean the nozzle