109
Power Trim Does Not Operate
(Motor Doesn’t Run)
Possible Cause Remedy
Blown fuse.
Loose or dirty electrical
connections or damaged
wiring.
Replace fuse.
Check all associated elec-
trical connections and
wires (especially battery
cables). Clean and tighten
faulty connection. Repair
or replace wiring.
Power Trim Does Not Operate (Motor Runs But
Drive Unit Does Not Move)
Possible Cause Remedy
Trim pump oil level low.
Drive unit binding in
gimbal ring.
Fill pump with oil.
Check for obstruction.