Host Communication: Ethernet: 10-BaseT/100Base-TX and Micro USB port (2.0) with optional adapter:
pluggable model USB2-OTGE100
Serial I/O Device: Two each: 2-wire RS-485, 2,400 to 115,200 bps, asynchronous, half-duplex, 1
start bit, 8 data bits, and 1 stop bit
Inputs: Two unsupervised dedicated for cabinet tamper and UPS fault monitoring
Cable requirements:
Power: 1 twisted pair, 18 AWG
Ethernet: Cat 5, minimum
RS-485: 1 twisted pair, shield, 120 ohm impedance, 24 AWG. 4,000 ft.
(1,219 m) maximum cable length
Environmental:
Temperature: -55 to +85 °C, storage
0 to +70 °C, operating
Humidity: 5 to 95 % RHNC
Mechanical:
Dimension: 5 in. (127 mm) W x 6 in. (152.4 mm) L x 1 in. (25 mm) H
Weight: 4.1 oz. (115 gm) nominal
UL294, 6
th
edition Performance Levels:
Feature
Level
Standby Power
I
Endurance
IV
Line Security
I
Destructive Attack
I
These specifications are subject to change without notice.
Warranty
Mercury Security warrants the product is free from defects in material and workmanship under normal use and
service with proper maintenance for one year from the date of factory shipment. Mercury Security assumes no
responsibility for products damaged by improper handling or installation. This warranty is limited to the repair
or replacement of the defective unit.
There are no expressed warranties other than set forth herein. Mercury Security does not make, nor intends,
nor does it authorize any agent or representative to make any other warranties, or implied warranties, and
expressly excludes and disclaims all implied warranties of merchantability or fitness for a particular purpose.
Returns must be accompanied by a Return Material Authorization (RMA) number obtained from customer
service, and prepaid postage and insurance.
Liability
The Interface should only be used to control exits from areas where an alternative method for exit is available.
This product is not intended for, nor is rated for operation in life-critical control applications. Mercury Security
is not liable under any circumstances for loss or damage caused by or partially caused by the misapplication or
malfunction of the product. Mercury Security's liability does not extend beyond the purchase price of the
product.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mercury LP2500 and is the answer not in the manual?

Mercury LP2500 Specifications

General IconGeneral
BrandMercury
ModelLP2500
CategoryController
LanguageEnglish

Related product manuals