er/technician. Read and follow this manual, all supplements and related
instructional information provided with the boiler. Install, start and service the boiler only in the sequence and methods given in these
instructions. Failure to do so can result in severe personal injury, death or substantial property damage.
Do not use the boiler during construction. Construction dust and particulate, particularly drywall dust, will cause contamination of
the burner, resulting in possible severe personal injur
e boiler can only be operated with a dust-
free air supply. Follow the instruction manual procedures to duct air to the boiler air intake. If the boiler has been contaminated by operation
with contaminated air, follow the instruction manual guidelines to clean, repair or replace the boiler if necessary.
x these instructions near to the boiler/water heater. Instruct the building owner to retain the instructions for future use b
service technician, and to follow all guidelines in the Users Information Manual.
er/technician. Read and follow this manual, all supplements and related
instructional information provided with the boiler. Install, start and service the boiler only in the sequence and methods given in these
instructions. Failure to do so can result in severe personal injury, death or substantial property damage.
Do not use the boiler during construction. Construction dust and particulate, particularly drywall dust, will cause contamination of
the burner, resulting in possible severe personal injur
e boiler can only be operated with a dust-
free air supply. Follow the instruction manual procedures to duct air to the boiler air intake. If the boiler has been contaminated by operation
with contaminated air, follow the instruction manual guidelines to clean, repair or replace the boiler if necessary.
x these instructions near to the boiler/water heater. Instruct the building owner to retain the instructions for future use b
service technician, and to follow all guidelines in the User’s Information Manual.
KNV3-0214
Cast Iron Condensing Boilers
Models
KN
-
6, KN-10, KN-16,
KN-20, KN-26
and KN-30
V3
Also read and follow:
KN-Series Gas Boiler Installation
and Operating Instructions
This instruction manual applies only to Advanced
Thermal Hydronics firmware version 1.x on version
3.x control boards. Current firmware is backwards
compatible with version 1.x & 2.x boards, but some
current features may not be available. To replace
firmware on an existing boiler, contact the factory
to obtain the original firmware file or for assistance
in applying current firmware to an olde
r version
control board.
Control adjustment and operation instructions
for Advanced Thermal Hydronics firmware
version 1.08

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Mestek HeatNet V3 and is the answer not in the manual?

Mestek HeatNet V3 Specifications

General IconGeneral
BrandMestek
ModelHeatNet V3
CategoryControl Panel
LanguageEnglish

Summary

Setup and Operation

Basic Multi Boiler System Operation

Explains configuring a system with Master and Member boilers using H-Net.

Mixed Boiler System Configuration

Details using priority sets to manage mixed boiler types for economy and performance.

Mixed Boiler System Operation

Describes starting and stopping boilers in mixed systems based on priority and conditions.

Start/Stop Priority Conditions

Configures firing and stopping priorities for mixed condensing/non-condensing boilers.

Selecting Mixed Boilers

Factors for choosing boilers in mixed systems: turndown, BTUs, and system design.

Control Methods

Base Loading and Relay Control

Explains enabling base load feature using relay K8 and associated configuration settings.

Heating Control Methods

Describes five methods for controlling KN series boilers via PID, stage, or communications.

Input Priorities

Explains the prioritization of external control inputs for boiler operation.

Heating Method 1: Heat Demand

Controls boiler via HEAT DEMAND input for setpoint control and Master/Member interaction.

Heating Method 2: Stage Control T1-T2

Operates boiler in two stages using T1/T2 inputs for external stage controllers.

Heating Method 3: 4-20mA Control

Uses 4-20mA input for remote control of boiler firing rate and modulation.

Optional Features

Failsafe Modes

Protects systems from heat loss via BMS failure or H-Net communication loss failsafe.

Domestic Hot Water Methods

Supports four methods for DHW control, including tank sensor input and space heating integration.

Wiring Connections

Boiler Calibration

SETUP Menu Default Settings

ADVANCED SETUP Default Settings

MODBUS Communications

Troubleshooting Common Issues

Status Screen Fault Display