Do you have a question about the Metabo Basic 250-50 W and is the answer not in the manual?
Motor power | 1500 W |
---|---|
Power source | AC |
AC input voltage | 220 - 240 V |
AC input frequency | 50 Hz |
Intake capacity | 200 l/min |
Maximum airflow | 110 l/min |
Air tank capacity | 50 L |
Sound power level | 97 dB |
Sound pressure level | 81 dB |
Pump motor speed (max) | 2850 RPM |
Maximum operating pressure | 8 bar |
On/off switch | Yes |
Product color | Black |
Housing material | - |
Depth | 400 mm |
---|---|
Width | 780 mm |
Height | 625 mm |
Weight | 32000 g |
Cord length | 1.5 m |
Ensures safety in the work area, covering lighting, explosive atmospheres, and keeping children away.
Covers safe use of power tools regarding cords, earthed surfaces, and outdoor use.
Focuses on user alertness, protective equipment, preventing unintended starts, and appropriate clothing.
Guidelines for proper tool operation, maintenance, and avoiding misuse for safety and performance.
Emphasizes using qualified personnel and genuine parts for device servicing to ensure safety.
General advice for users, including supervision for inexperienced individuals and manufacturer liability.
Warns against directing compressed air at people/animals and ensuring tool compatibility with pressure.
Details safe usage of oil-containing compressed air for compatible tools and avoiding contamination.
Advises allowing the tool to cool down before servicing to prevent burns.
Instructs not to operate the tool without installed guards to prevent crushing injuries.
Instructions for mounting tyres, rubber feet, and attaching the air filter.
Ensures the condensate outlet is properly closed before operation.
Procedure for checking and filling the compressor oil level according to specifications.
Requirements for the device's positioning site: dry, protected from frost, stable, and accessible.
Guidance on safe transport of the device, avoiding mains cable and using the transport handle.
Details on safe electrical connection, including voltage, fuses, RCD, and cable requirements.
Steps to switch on, reach pressure, set regulator, connect tools, and switch off the compressor.
Maintenance tasks for every 250 hours of operation, including oil level check.
Maintenance tasks for every 500 hours of operation, including oil drainage and replacement.
Recommendation for inspection by an authorized service center to increase compressor lifespan.
Troubleshooting steps for when the compressor fails to start or operate.
Diagnosing and resolving issues where the compressor runs but does not build sufficient pressure.
Troubleshooting insufficient pressure at the compressed air tool, checking regulator and hose connections.