EasyManua.ls Logo

Meva Mammut XT Manual

Default Icon
19 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Wall formwork Mammut XT
90° corner – Single-sided tying
Fig. 40.1
MammutXT inside corner
MammutXT panel w = 25 cm
M alignment rail 75
Single-sided tying
For single-sided tying at the
corner a 25 mm wide XT panel
is installed next to the XT inside
corner and next to the XT panel
opposite (50 or 75cm wide)
(Figures40.1 to 40.4).
For stabilisation, an M alignment
rail75 is fitted to the multi-
function profile of the panel
across the 25 cm wide panel
(Figures40.1 and 40.2).
The number of alignment rails
depends on the number of tie
holes in the panel.
For pouring heights up to
350cm and wall thicknesses up
to 30cm the M alignment rail is
not required (Figures.40.3 and
40.4 and Table4444.6).
Attention
Unused tie holes must always
be closed with plug D35/38 or
alternatively with XT sealing cone
(10) with a pressed-on plugD20
(see page XT-18).
M alignment rail 75
MammutXT outside corner
Description Ref. No.
M alignment rail 75 .............. 29-400-95
Flange screw 18 .................... 29-401-10
XT sealing cone ..................... 29-902-34
XT sealing cone 10 ................ 29-902-35
Plug D35/38 .......................... 29-902-71
Plug D20, red ........................ 29-902-63
Fig. 40.2
Fig. 40.3
Fig. 40.4
MammutXT outside corner
MammutXT
panel w = 25 cm
MammutXT inside corner
Single-sided tying
Pouring heights up to 350cm
and wall thicknesses up to
30cm
Pouring heights and wall
thickness as required
XT-40 Technical Instruction Manual / Status September 2018