3640DCT EM-9538-B Rev.5
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
5. PARAMETER CONFIGURATION
■ MODE
Parameters can be grouped in several modes.
The 40DCT has modes as shown in the following table.
MODE FUNCTION MEASUREMENT
Measuring Normal measurement state where the unit takes in input. When the power is supplied,
the unit operates in Measuring Mode.
Measuring
Scaling Setting Decimal point position, input scaling value A and B, display scaling value A and B,
low-end cutout and low-end cutout value can be set.
Measuring stopped
Display Setting Moving average and brightness can be set. Settings can be initialized. Also the rm-
ware version can be conrmed.
■ MODE TRANSITION
■ TRANSITION FROM MEASURING MODE TO EACH MODE
To Scaling Setting Mode
Hold down S
CALE/↑ button for 3 seconds or more.
To Display Setting Mode
Hold down D
ISP/↓ button for 3 seconds or more.
■ TRANSITION FROM EACH MODE TO MEASURING MODE
Hold down D
ISP/↓ or SCALE/↑ button for 1 second or more to return to Measuring Mode.
POWER ON
Measuring
Mode
Display Setting Mode
Hold down S
CALE
/
↑
for ≥ 3 sec.
Scaling Setting Mode
for ≥ 3 sec.
Hold down D
ISP
/
↓
Hold down
D
ISP
/
↓
or S
CALE
/
↑
Hold down
D
ISP
/
↓
or S
CALE
/
↑