8.2 LOW-END CUTOUT VALUE
8.2.1 OPERATING PROCEDURE
1
Hold down SCALE/ button for 3 seconds or more to move on to
Scaling Setting Mode.
• The setting item ‘D PT’ (decimal point position) is indicated.
2
Press DISP/ or SCALE/ button to go to the low-end cutout value
setting.
• The setting item ‘LIMN’ (low-end cutout value) is indicated.
3
Press SHIFT button to show the setting and SCALE/ button to shift
the display into the setting standby mode.
• The third digit starts blinking, to which you can apply changes.
4
Press DISP/ or SCALE/ button to go to the next digit, and UP button
to change the blinking value.
• Set within the range of 000 to 999.
NOTE
Set the value for the display scaling. The decimal point is not indicated.
2,4,
6
1,2,
3,4,6
3,5
4
Blinking
Blinking