1443DV2 EM-9422-B Rev.3
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
1.6.6 WIRING HOLD INPUT
Displayed value is held with an external HOLD command input.
Connect the contact across HOLD to COM as shown in the following gure.
Close the contact to hold the value.
Detecting voltage Approx. 2.1 V DC, 0.03 mA
Detecting level ≤ 0.8 V
IMPORTANT
• Be sure to conrm the input polarity in wiring.
• The HOLD input is not isolated from the internal circuit.
HOLD input
COM HOLD
34
■ WIRING EXAMPLES
L
HOLD
H
3
Twisted pair cable
L
HOLD
H
L
HOLD
H
L
HOLD
H
Twisted pair cable
Twisted pair cable
COM
3
4
COM
(b)
Transistor
(a)
5V–CMOS, TTL
(c)
Photo-Coupler
(d)
Relay
Relay
Photo-Coupler
HOLD
4
HOLD
3
Twisted pair cable
COM
4
HOLD
3
4
COM
HOLD