1843DV2 EM-9422-B Rev.3
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
2.2 BASIC SETTING OPERATION
Parameters can be grouped into three setting types, “numerical value setting”, “setting value selection” and “decimal point
position selection”. Basic operation of each type is as shown below.
■ NUMERICAL VALUE SETTING
1
Press SF button to shift the display into the setting standby mode.
• The 4th digit starts blinking.
2
Press SF and UP buttons to set a numerical value.
• Press S
F button to go to the next digit.
• Press U
P button to change the blinking value.
3
Press DI or SC button to apply the new setting.
• The next or previous parameter setting is indicated.
NOTE
■ SHIFTING DIGITS
Each time pressing S
F button, the blinking digit moves to the right.
■ SETTING A NUMERICAL VALUE
• Each time pressing U
P button, the numeral is incremented by 1.
• The negative sign (-) must be set together with the 4th digit. For example, set ‘-04.0’ instead of ‘-4.0’.
• 4th digit
• Other digits
*1 Display depands on the settings.