5643DV2 EM-9422-B Rev.3
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
13.2 MODEL NUMBERING
Code number: 43DV2–[1][2]–R[3]
[1] INPUT
DC voltmeter (without scaled range)
V1: ±199.9 mV DC (input resistance ≥ 1 MΩ)
V2: ±1.999 V DC (input resistance ≥ 1 MΩ)
V3: ±19.99 V DC (input resistance ≥ 1 MΩ)
Process meter
S4: 0 – 10 V DC (input resistance ≥ 1 MΩ)
S5: 0 – 5 V DC (input resistance ≥ 1 MΩ)
S6: 1 – 5 V DC (input resistance ≥ 1 MΩ)
S0: Specify voltage (see INPUT SPECIFICATIONS)
SA: 4 – 20 mA DC (input resistance 20 Ω)
SB: 0 – 20 mA DC (input resistance 20 Ω)
SC: 0 – 10 mA DC (input resistance 40.2 Ω)
SG: 0 – 1 mA DC (input resistance 402 Ω)
SJ: 0 – 5 mA DC (input resistance 80.6 Ω)
SZ: Specify current (see INPUT SPECIFICATIONS)
[2] TERMINAL BLOCK
S: Screwless spring terminal
D: Separable screwless spring terminal
POWER INPUT
DC Power
R: 24 V DC (operational voltage range 24 V ±10%, ripple 10% p-p max.)
[3] OPTIONS
Blank: None
/Q: With options (specify the specication)
SPECIFICATIONS OF OPTION: Q
EX-FACTORY SETTING
/SET: Preset according to the Ordering Information Sheet (No. ESU-9422)