MicroNova O047 - User Manual

MicroNova O047
113 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
immagine
O047+T047 idro
O047+T047 hydro
MANUALE TECNICO
PER LINSTALLATORE
TECHNICAL INSTALLATION
MANUAL
Question and Answer IconNeed help?

Do you have a question about the MicroNova O047 and is the answer not in the manual?

Summary

OPERATING MODE

Standby status

Defines conditions for the stove to enter standby mode, switching off temporarily.

7.10.4 Puffer t-e (PUFF T-E)

Mode where the stove heats the puffer water controlled by an external thermostat.

7.11 Switching off the stove

Procedure to turn off the stove using the P4 button and subsequent fan operation.

USER MENU

8. MENU

Overview of the menu structure for accessing settings and system programming.

8.2 Menu 01 - SET CLOCK

Setting the current time and date for the stove's internal clock.

8.3 Menu 02 - SET CHRONO

Enables/disables and configures daily and weekly chronothermostat functions.

8.4 Menu 03 - LANGUAGE SELECTION

Allows selection of the user interface language for the control panel.

8.5 Menu 04 - CHOOSE SEASON

Selects the season (winter/summer) to exclude heating functions during summer.

8.6 Menu 05 - STAND-BY MODE

Enables or disables the standby mode for temporary stove shutdown.

8.7 Menu 06- BUZZER MODE

Allows enabling or disabling the audible buzzer on the controller.

8.8 Menu 07 - FIRST CHARGE

Allows loading the pellet screw on the first stove startup when the tank is empty.

8.9 Menu 08 - STOVE STATUS

Displays various operational variables and parameters of the stove.

8.10 Menu 09 - TECHNICAL SETTINGS

Access to technical parameters for installation and configuration by qualified personnel.

8.11 Menu 10 - PELLET TYPE

Adjusts the pellet loading percentage for different pellet types.

8.11 Menu 10 - CHIMNEY TYPE

Modifies the fume fan speed percentage for chimney draft optimization.

10.5 M-9-5 Reset partial hours

Resets the partial operating hours counter for the stove.

10.6 M-9-6 Reset alarms

Resets the stored alarm memory banks in the control system.

10.7 M-9-7 Meter memory

Displays and manages stored alarm and time counter memory banks.

ALARMS

9. ALARMS

Overview of system alarms, their causes, and how they are signaled.

9.1 Black-out

Alarm triggered by a power outage during operation, with specific restart conditions.

9.2 Smoke temperature probe alarm

Alarm indicating a faulty smoke temperature probe, leading to stove shutdown.

9.3 Smoke over-temperature alarm

Alarm for excessive exhaust probe temperature, causing the stove to shut down.

9.4 Smoke encoder alarm

Alarm for a faulty air ventilator or smoke encoder, resulting in stove shutdown.

9.5 Ignition failure alarm

Alarm when the ignition phase fails due to temperature not rising as expected.

9.6 Pellet absence alarm

Alarm triggered when smoke temperature drops below a threshold during operation, indicating no pellet.

9.7 Overtemperature thermal safety alarm

Alarm from the general safety thermostat detecting excessive temperature, shutting down the stove.

9.8 Depression failure alarm

Alarm when the pressure switch detects low pressure/depression, stopping the auger.

9.9 Water probe alarm

Alarm indicating the water probe is not connected to the circuit, causing shutdown.

9.10 Overtemperature water probe

Alarm if the water probe detects a very high temperature, shutting down the stove.

9.11 Alarm pressure water

Alarm triggered by external water pressure switch detecting pressure outside set thresholds.

TECHNICAL MENU

10. TECHNICAL MENU

Access for technicians to configure product parameters, with safety warnings.

10.1 M-9-1 Database

Access to predefined settings (data banks) for adapting the stove to different types.

10.2 M-9-2 General settings

Access to various adjustable parameters for system configuration.

10.3 M-9-3 Outputs test

Function to test the controller's outputs, available only when the stove is off.

10.4 M-9-4 Factory settings

Access to factory configuration parameters for detailed setup and adjustments.

10.5 M-9-5 Reset partial hours

Resets the partial operating hours counter for the stove.

10.6 M-9-6 Reset alarms

Resets the stored alarm memory banks in the control system.

10.7 M-9-7 Meter memory

Displays and manages stored alarm and time counter memory banks.

DATABASES

11. DATABASES

Explanation of the control board's memory structure and data access modes.

11.1 Structure of the control board memory

Block diagram illustrating memory structure, EEPROM, and FLASH memory access.

11.2 Create personalized databases (*).

Guide to creating and memorizing custom databases using PC software and serial connection.

FIRMWARE UPDATE

12. FIRMWARE UPDATE (*).

Procedure to update the control board's operating software using a PC and specific firmware files.

APPENDIX A

13. APPENDIX A: Parameter table

Table listing all configurable parameters, their menus, descriptions, and operating ranges.

APPENDIX B

14. APPENDIX B: Start up sequence and working conditions

Diagrams illustrating the stove's start-up sequence and operational conditions.