Defines conditions for the stove to enter standby mode, switching off temporarily.
Mode where the stove heats the puffer water controlled by an external thermostat.
Procedure to turn off the stove using the P4 button and subsequent fan operation.
Overview of the menu structure for accessing settings and system programming.
Setting the current time and date for the stove's internal clock.
Enables/disables and configures daily and weekly chronothermostat functions.
Allows selection of the user interface language for the control panel.
Selects the season (winter/summer) to exclude heating functions during summer.
Enables or disables the standby mode for temporary stove shutdown.
Allows enabling or disabling the audible buzzer on the controller.
Allows loading the pellet screw on the first stove startup when the tank is empty.
Displays various operational variables and parameters of the stove.
Access to technical parameters for installation and configuration by qualified personnel.
Adjusts the pellet loading percentage for different pellet types.
Modifies the fume fan speed percentage for chimney draft optimization.
Resets the partial operating hours counter for the stove.
Resets the stored alarm memory banks in the control system.
Displays and manages stored alarm and time counter memory banks.
Overview of system alarms, their causes, and how they are signaled.
Alarm triggered by a power outage during operation, with specific restart conditions.
Alarm indicating a faulty smoke temperature probe, leading to stove shutdown.
Alarm for excessive exhaust probe temperature, causing the stove to shut down.
Alarm for a faulty air ventilator or smoke encoder, resulting in stove shutdown.
Alarm when the ignition phase fails due to temperature not rising as expected.
Alarm triggered when smoke temperature drops below a threshold during operation, indicating no pellet.
Alarm from the general safety thermostat detecting excessive temperature, shutting down the stove.
Alarm when the pressure switch detects low pressure/depression, stopping the auger.
Alarm indicating the water probe is not connected to the circuit, causing shutdown.
Alarm if the water probe detects a very high temperature, shutting down the stove.
Alarm triggered by external water pressure switch detecting pressure outside set thresholds.
Access for technicians to configure product parameters, with safety warnings.
Access to predefined settings (data banks) for adapting the stove to different types.
Access to various adjustable parameters for system configuration.
Function to test the controller's outputs, available only when the stove is off.
Access to factory configuration parameters for detailed setup and adjustments.
Resets the partial operating hours counter for the stove.
Resets the stored alarm memory banks in the control system.
Displays and manages stored alarm and time counter memory banks.
Explanation of the control board's memory structure and data access modes.
Block diagram illustrating memory structure, EEPROM, and FLASH memory access.
Guide to creating and memorizing custom databases using PC software and serial connection.
Procedure to update the control board's operating software using a PC and specific firmware files.
Table listing all configurable parameters, their menus, descriptions, and operating ranges.
Diagrams illustrating the stove's start-up sequence and operational conditions.