closed and two minutes later, the change valve is closed. The indoor blower fan is running at the set speed. 
Restart up six minutes later; if the above situations appear again within ten minutes, all the outputs are shut 
down through the electric control board and display failure. 
●  When you press turbo button of remote, the air conditioner enter turbo running, compressor ,outdoor blower 
fan and four-way valve turn on all along, indoor blower fan run at high speed and it must meet start 
condition, turbo indication is light. 
●  After the compressor runs five minutes, the lamp flashes 4 times per six seconds or display E4 if the 
temperature of indoor coil pips is less than 30℃  (heating) in the continuous 20 minutes. The controller will 
automatically shut down if the temperature of indoor coil pips is less than 30℃  in another continuous 20 
minutes, that is the abnormality protection of outdoor units and the indicator lamp keeps its former state of 
flashing. 
+